 Fig. from left to right: SAA 901, SAA 2003, SAA 3003 Arguments which will convince you: - for milling, planing and drilling chips (no dust)
- ventilator made of metal, of blade shape for enhanced suction performance
- stable construction made of massive steel plate, no fragile plastic material
- low static loading compared to any plastic material constructions
- high suction performance and very quiet
- easy movable with steering rollers
- perfect price-performance ratio
 SAA 901
| model | SAA 1001 | SAA 2003 | SAA 3003 |
|---|
| Item no. | 592 2101 | 592 2203 | 592 2303 | | EUR excl. VAT | 189,00 | 319,00 | 459,00 |
|---|
| | Technical data |
|---|
| suction performance | 850 m³/h | 2.553 m³/h | 3.910 m³/h | | Nozzle inlet | Ø 100 mm | Ø 125 mm | Ø 150 mm | | Nozzle outlet | 1 x Ø 100 mm | 2 x Ø 100 mm | 3 x Ø 100 mm | | Power supply | 230 V / 1~ 50 Hz | 400 V / 3~ 50 Hz | 400 V / 3~ 50 Hz | | Engine power | 750 Watt | 1.500 Watt | 2.200 Watt | | Weight | 30 kg | 47 kg | 59 kg | |
| Extent of supply HOLZSTAR dust collectors for chips series SAA | Item no. | EUR excl. VAT |
|---|
Polyurethan flexible hose, transparent with spiral, flame resistant, available at lengths of 2,5 / 5,0 / 7,5 und 10,0 m Flexible hose Ø 38 mm | 514 2441 | 3,50 |
|---|
Polyurethan flexible hose, transparent with spiral, flame resistant, available at lengths of 2,5 / 5,0 / 7,5 und 10,0 m Flexible hose Ø 60 mm | 514 2445 | 4,30 |
|---|
| Flexible hose Ø 80 mm | 514 2442 | 4,90 |
|---|
Polyurethan flexible hose, transparent with spiral, flame resistant, available at lengths of 2,5 / 5,0 / 7,5 und 10,0 m Flexible hose Ø 100 mm | 514 2443 | 5,50 |
|---|
Polyurethan flexible hose, transparent with spiral, flame resistant, available at lengths of 2,5 / 5,0 / 7,5 und 10,0 m Flexible hose Ø 120 mm | 514 2444 | 6,20 |
|---|
Exhaust hose, Ø 100 mm/2,5 m, transparent with spiral Exhaust hose, Ø 100 mm/2,5 m, transparent | 514 2401 | 19,95 |
|---|
Floor cleaning kit 1 - for all suction plants
- including high-quality 2,5 m spiral hose, suction tube, floor nozzle
with roles, handle and 2 brackets Floor cleaning kit 1 | 514 8100 | 179,00 |
|---|
Automatic starting for suction plants - when the wood working machine is being switched on, the suction plant will automatically start with a delay of 2-3 sec., the additional switching on of the suction plant is omitted
- when switching the working machine off, the suction plant will run for about 3-4 sec. longer.
- the remaining dustwill be sucked off after switching off the working machine according to the Ordinance on Hazardous Substances
- additional protection of overload of the mains fuse when switching on
ALA 2 | 512 1501 | 59,00 |
|---|
Automatic starting for suction plants - when the wood working machine is being switched on, the suction plant will automatically start with a delay of 2-3 sec., the additional switching on of the suction plant is omitted
- when switching the working machine off, the suction plant will run for about 3-4 sec. longer.
- the remaining dustwill be sucked off after switching off the working machine according to the Ordinance on Hazardous Substances
- additional protection of overload of the mains fuse
when switching on ALA 10 | 512 1502 | 139,00 |
|---|
| Accessories: 
Polyurethane flexible hose
- transparent with spiral
- flame resistant
- available at lengths of 2.5 / 5.0 / 7.5 or 10.0 m
 Floor cleaning kit 1 - For all suction plants
- Including high-quality 2.5 m spiral hose,suction tube, floor nozzle with roles, handle and 2 clamps

Reducing coupling Machine connection - straight, not flanged, innerØ
- Ø 100/60 mm

Automatic starting for suction plants - When the wood working machine is being switched on, the suction plant will automatically start with a delay of 2-3 sec., the additional switching on of the suction plant is omitted.
- When switching the working machine off, the suction plant will cast for about 3-4 sec. longer
- The remaining dust will be sucked off after switching off the working machine according to the Ordinance on Hazardous Substances
- Additional protection of overload of the mains fuse when switching on
|